| Customization: | Available |
|---|---|
| Charge Method: | Normal Charge |
| Installation: | with The Car |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Rated Output Power | 20kW | 30kW | 40kW |
| Adjustable Current Range | 0~50A | 0~80A | 0~100A |
| Output Voltage | 200VDC~750VDC | ||
| Adjustable Current Limiting Range | 10%~110%Stepless adjustment | ||
| Peak Level Noise | ≤1% | ||
| Voltage Regulation Accuracy | ≤0.5% | ||
| Harmonic Current | ≤5% | ||
| Leakage Current | ≤30mA | ||
| Steady Flow Accuracy | ≤1% | ||
| Current Sharing | ≤±5% | ||
| Efficiency | ≥93% | ||
| Duty Cycle | 95 % | ||
| Rated Input Voltage | 380Vac±15%(Three-phase five-wire system) | ||
| Load Rating | Continuous operation at 10%-110% of the rated output current | ||
| Input Voltage Range | 323Vac~437(Fully loaded) 305Vac~260Vac(Down to half load) |
||
| Frequency | 49Hz~51Hz | ||
| Power Factor(PF) | ≥0.99 | ||
| Electrical Loss Fidelity(THD) | ≤5% | ||
| MTBF | >8760h | ||
| Auxiliary Power Output | Rated at 12V | ||
| Cable Length | ≥3M | ||
| AC Input Overvoltage Protection | 437V±10V | ||
| AC Input Undervoltage Alarm | 323±10V | ||
| DC Output Overvoltage Protection | 760V±10V | ||
| DC Output Undervoltage Alarm | 200V~250V | ||
| DC Output Current Limit | 0~105% rated output | ||
| Output Short-Circuit Protection | Shutdown Alarm | ||
| Overheat Protection | ≥ 65±5°C shutdown alarm | ||